Two Caterpillar Generators (1000 KVA And 700 KVA)

SaleSpider Left Classified Main Image
Salvex Listing ID: 182968460
Item Details:

These Two Caterpillar Generators (1000 KVA and 700 KVA) are available as a result of a casualty claim and are being offered for sale by the insurance co. as part of the mitigation process. Please see details.

Caterpillar 1000KVA Generator (Will run, but will not hold load over 5 minutes)

Generator model: SR-4 (Series S)
Manufactured: 2002
Hours: 628
Power: 1000 KVA
Voltage & Current: 480 V & 1503 A
KW: 100
Contunuous rating: 600V AC with 6A (3 phase)
RPM: 1800 rpm
Engine power: 1489 HP
Fuel type: Diesel powered
Operation: 628 hours
Frame model & size: 257-04622 & AR#7C1299
Serial Number: 6MA01043
Management Number: 7C-1618

Caterpillar 700KVA Generator (With burnt windings. Engine not damaged)

Generator model:
Manufactured: 10/1992
Power: 700 KVA
Voltage: 480 V
Contunuous rating: 600V AC with 6A (3 phase)
RPM: 1800 rpm
Engine power: 1489 HP
Fuel type: Diesel powered
Operation: 632 hours
Frame size: AR#7C1000
Serial Number:
Management Number:

Service Cabinets (6 units)

Each contains multiple gauges, switches, and breakers. Stand by controller/ breaker panel is not damaged and was built in 2000
Note: If succesful bidder wants free loading of the two units, they only need to bring two flatbed trucks on site on September 23, 2016 by 9:00 AM. There will be no charge for the loading of the generators on that day only.

Quantity: 2 Generators
Claim Value: $320,000.00
Location: Hudson, Florida, United States
These two generators were affected when a lightning strike hit the main power cables leading from the mechanical room to the main building. The standby generators then tried to take the electrical load, but the switch to which the standby generators are connected is also connected to the electrical wires that were burned. Thus, the standby generators tried to send power through the electrical lines that were damaged by the lightning strike. The generators are timed so the 700 KV activates at the loss within 0.3 seconds of the loss of power. If additional power is needed, the 1000 KV unit then starts about 1 second. Thus, the 700 KV took the initial back feed through the damaged wires resulting in the burned generator windings. The 1000 kv appears to have the windings in reasonable condition, but the unit would not continue to run except for a short period. Damages to the 1000KV are not identified. Photos were taken on 9/07/16. All items are sold "AS IS, WHERE IS". The buyer is responsible for shipping and handling.
Seller Terms:
This product is purchased, as is where is basis, buyer is responsible for all moving and freight costs. The seller does not offer any warranties or any manufacturer warranties. Upon receipt of cleared funds, seller will give the buyer a release order for item pick up. All product sold as is, where is.
Go to aucID=182968460 to view complete listing (with photos) and place your bid. Contact Juan Rosales at 713-229-9000 x132 or 713 229 9000 if you have specific questions pertaining to this listing.
September 16, 2016
Hudson, Florida

Share This Classified With Your Social Networks

Subscribe to this RSS Feed

Member Spotlight

Charles Pafford Icon
Charles Pafford
Invisus Direct
Independant Contractor

Business Spotlight

Turke Orthodontics Icon
Turke Orthodontics
Two Caterpillar Generators (1000 KVA and 700 KVA)